Chambers' AC3 Controller Program
Last Updated: 08/04/07
Timers:
- VHO$-B4
- MH1$-A7
- MH2$-A8
- COL&-C1
- CEH&-C3
- HET&-C4
- FAN&-B6
- CO2&-A1
- RET#-B2
- CLP#-A6
- SKM#-C2
- STR#-A5
- KLK#-A4
- MON$-D1
- FUG$-A2
- AIR&-B7
- H2O&-B5
- WLT&-B1
- MPR&-B8
- SW1&-A10
- ALM&-A9
Program:
- If Time > 00:00 Then RET ON
- If Time > 00:00 Then SKM ON
- If Time > 00:00 Then CLP ON
- If Time > 00:00 Then AIR ON
- If Time > 00:00 Then WLT ON
- If Time > 00:00 Then MPR ON
- If Time > 00:00 Then CO2 ON
- If pH < 07.90 Then CO2 OFF
- If pH2 < 06.70 Then CO2 OFF
- Max Change 010 M Then CO2 OFF
- If Switch1 CLOSED Then SW1 ON
- If Switch1 OPEN Then SW1 OFF
- Max Change 005 M Then SW1 OFF
- If Time > 23:00 Then STR ON
- If Time > 23:02 Then STR OFF
- If Time > 00:00 Then KLK ON
- If Time > 04:00 Then STR ON
- If Time > 04:02 Then STR OFF
- If Time > 08:30 Then STR ON
- If Time > 08:32 Then STR OFF
- If Time > 13:00 Then STR ON
- If Time > 13:02 Then STR OFF
- If FeedD 000 Then STR ON
- If Time > 16:00 Then KLK OFF
- If Timer STR = ON Then KLK OFF
- If pH > 08.35 Then KLK OFF
- Max Change 030 M Then KLK OFF
- If Timer SW1 = OFF Then KLK OFF
- If Time > 16:00 Then H2O ON
- If Time > 19:00 Then H2O OFF
- If Moon 000/000 Then MON ON
- If Timer VHO = ON Then MON OFF
- If Time > 10:30 Then VHO ON
- If Time > 11:00 Then MH1 ON
- If Time > 11:05 Then MH2 ON
- If Time > 21:00 Then MH1 OFF
- If Time > 21:00 Then MH2 OFF
- If Time > 22:00 Then VHO OFF
- If Time > 21:55 Then MON ON
- If Time > 03:30 Then MON OFF
- If Time > 20:00 Then FUG ON
- If Time > 10:00 Then FUG OFF
- If Temp > 80.8 Then MH2 OFF
- If Temp > 81.0 Then MH1 OFF
- If Temp > 81.2 Then VHO OFF
- If Temp > 81.4 Then CLP OFF
- If Temp > 78.7 Then FAN ON
- If Temp < 78.5 Then FAN OFF
- If Temp > 80.0 Then COL ON
- If Temp < 79.5 Then COL OFF
- If Temp > 99.9 Then COL OFF
- If Timer RET = OFF Then COL OFF
- Max Change 015 M Then COL OFF
- If Timer COL = ON Then CEH ON
- If Temp < 78.7 Then HET ON
- If Temp > 79.0 Then HET OFF
- If Temp < 70.0 Then HET OFF
- Max Change 015 M Then MH1 OFF
- Max Change 015 M Then MH2 OFF
- Max Change 005 M Then VHO OFF
- If FeedA 000 Then RET OFF
- If FeedB 000 Then RET OFF
- If FeedB 000 Then VHO ON
- If Time > 12:00 Then ALM ON
- If Time > 12:01 Then ALM OFF
- If pH > 08.40 Then ALM ON
- If pH < 07.80 Then ALM ON
- If Temp < 77.5 Then ALM ON
- If Temp > 81.5 Then ALM ON
- If Power 000 Then ALM ON
- If Power 000 Then SKM OFF
- If Power 000 Then WLT OFF
- If Power 000 Then AIR OFF
- If Power 000 Then H2O OFF
- If Power 005 Then COL OFF
- If Power 005 Then HET OFF
- If Power 002 Then VHO OFF
- If Power 010 Then MH1 OFF
- If Power 011 Then MH2 OFF
- If Power 003 Then CLP OFF
- If Power 000 Then CO2 OFF
- If Power 000 Then MON OFF